When to check or replace the lens
- Weld quality drops, or the laser starts strong and then becomes weak so that the wire no longer melts.
- A lens temperature alarm appears – check the lens for damage first.
- The lens is dirty or shows visible burn spots – replace it.
- Some guns allow the protective lens to be turned in its window; if turning it several times does not help, the lens is damaged and must be replaced.
Step by step
- Switch off the machine.
- Wash and dry your hands, then wipe them with alcohol-moistened cotton (or wear clean gloves).
- In a place as dust-free as possible, remove the screws of the lens cover and pull out the lens holder; cover the open chamber (e.g. with masking tape).
- Inspect the protective lens – replace it if it shows burn spots or contamination. Do not touch the optical surface; no fingerprints.
- Check the white sealing ring under the lens – replace it immediately if it is scratched or deformed.
- Wipe the chamber opening and the inside of the cover with alcohol-moistened cotton, insert the lens holder quickly and tighten the screws.
- Before welding, check that the red pilot light exits the centre of the nozzle.
Prevent lens damage
- Always turn on the shielding gas before testing or welding – otherwise the optical lenses can be damaged.
- Keep the work area clean and handle the gun gently.
- Protective, focusing and collimating lenses are wear parts.
- Use the lens size specified for your gun. Protective lenses are listed by diameter × thickness (e.g. D18 × 2 mm) on our accessories page.
Source: compiled from the operating manuals and product documentation for RUVEN handheld laser welding machines. Always follow the manual supplied with your machine.